Component - Plastics | E41938 | |
E I DUPONT DE NEMOURS & CO INC | ||
ENGINEERING POLYMERS, CHESTNUT RUN PLAZA, PO BOX 80713, WILMINGTON DE 19880-0713 | ||
101(r9), 101F(r9), 101L(r9), E101(r9), E101L(r9) | ||
Polyamide 66 (PA66), "Zytel", furnished as pellets |
Min Thk | Flame | RTI | RTI | RTI | |||
Color | (mm) | Class | HWI | HAI | Elec | Imp | Str |
ALL | 0.4 | V-2 | 4 | 2 | - | - | - |
0.71 | V-2 | 4 | 0 | 130 | 75 | 85 | |
1.5 | V-2 | 3 | 0 | 130 | 75 | 85 | |
3.0 | V-2 | 2 | 0 | 130 | 75 | 85 |
Comparative Tracking Index (CTI): | 0 | Inclined Plane Tracking (IPT): | - |
Dielectric Strength (kV/mm): | 13 | Volume Resistivity (10x ohm-cm): | 14 |
High-Voltage Arc Tracking Rate (HVTR): | 0 | High Volt, Low Current Arc Resis (D495): | 6 |
Dimensional Stability (%): | - |
(r9) - | Virgin and regrind up to 50% by weight inclusive, have the same basic material characteristics for ALL colors down to 0.71mm. For thickness 0.40mm to 0.70mm the same basic material characteristics exist with the exception of generic RTIs for all properties and Regrind exceeding 25% is limited to V-2 Flammability for WT, RD, BK. |
NOTE - | (1) Material designations that are color pigmented may be followed by suffix letters and numbers. (2) Material designations may be prefixed by "ZYT" for Zytel or "MIN" for Minlon or "DEL" for Delrin or "CRA" for Crastin or "RYN" for Rynite or "ETPV" for ETPV or "SOR" for Sorona grades. |
ANSI/UL 94 small-scale test data does not pertain to building materials, furnishings and related contents. ANSI/UL 94 small-scale test data is intended solely for determining the flammability of plastic materials used in the components and parts of end-product devices and appliances, where the acceptability of the combination is determined by UL. |
Report Date: 1996-07-29 Last Revised: 2016-02-08 |
IEC and ISO Test Methods | ||||
Test Name | Test Method | Units | Thk (mm) | Value |
Flammability | IEC 60695-11-10 | Class (color) | 0.4 | V-2 (ALL) |
0.71 | V-2 (ALL) | |||
1.5 | V-2 (ALL) | |||
3.0 | V-2 (ALL) | |||
Glow-Wire Flammability (GWFI) | IEC 60695-2-12 | C | 0.4 | 960 |
0.71 | 960 | |||
1.5 | 960 | |||
3.0 | 960 | |||
Glow-Wire Ignition (GWIT) | IEC 60695-2-13 | C | 0.4 | 900 |
0.71 | 725 | |||
1.5 | 750 | |||
3.0 | 800 | |||
IEC Comparative Tracking Index | IEC 60112 | Volts (Max) | - | - |
IEC Ball Pressure | IEC 60695-10-2 | C | - | - |
ISO Heat Deflection (1.80 MPa) | ISO 75-2 | C | - | - |
ISO Tensile Strength | ISO 527-2 | MPa | - | - |
ISO Flexural Strength | ISO 178 | MPa | - | - |
ISO Tensile Impact | ISO 8256 | kJ/m2 | - | - |
ISO Izod Impact | ISO 180 | kJ/m2 | - | - |
ISO Charpy Impact | ISO 179-2 | kJ/m2 | - | - |